Operating Instructions Safety System CES-A-AEA-02B/CES-A-AEA-04B
29
Read head CES-A-LCA...
Ì Cube-shaped design 42 x 25 mm
Ì Plastic PE-HD housing material, suitable for use in aggressive media (e.g. ac-
ids, alkalis)
Dimension drawing
Note
The flat seal provided must be used during assembly.
Typical operating distance
With evaluation unit CES-A-AEA-01 and actuator CES-A-BCA
Note
For a side approach direction for the actuator and read head, a minimum distance
of s = 3 mm must be maintained so that the operating distance of the side lobes
is not entered.
Approvals
32
42
48
25
31
l
12
14
4,6
8
4,5
± 0,1
Active face
Active face
2 safety screws M4 x 14
are supplied
Flat seal
Side
lobe
N
-10-15 -5 0
Centre offset m [mm]
Distance s [mm]
OFF
ON
Switch-on
distance
ON
OFF
Hysteresis
Distance sS
ao
Output state
Switch-off
distance
OFF
Hysteresis
-20 5 201510
5
10
15
20
Side
lobe
N
Actuator
Read head
s
m
Comments to this Manuals