Euchner ActiveX Module Ethernet TCP/IP User Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
Manual EKS ActiveX
®
Module Ethernet TCP/IP
4.2 Example event call in Visual Basic
®
Private Sub EKS_OnKey( )
Select Case KeyState
Case EKS_EVENT_KEYIN
User functions KeyIn
' e. g. Read key data from the EKS Electronic-Key
' Attention! It is not necessary to call the Read method!
for i=0 to 123
KeyData = KeyData & EKS.Data(i)
Next i
Case EKS_EVENT_KEYOUT
User functions KeyOut
' e. g. Delete Electronic-Key data in the user software
KeyData = "-"
Case EKS_EVENT_OTHER
User functions Other
' e. g. Poll status number
StatusNumber = EKS.LastState
End Select
End Sub